TC Series “60”
GENERAL PUMPA member of the Interpump Group
TRIPLEX TRIPLEX
Triplex Plunger Pump
SERVICING INSTRUCTIONS
SERVICING PUMP PROCEDURES
General Pump
is a member of
the Interpump Group
8
Valve Replacement: All inlet and discharge valves can be serviced without disrupting the inlet or discharge
plumbing. The inlet and discharge valves are identical in all 63 series models.
To service any valve:
1) Remove valve cap and examine o-ring. Replace o-ring if there is any
evidence of cuts, abrasions, distortion or wear.
2) Remove valve assembly (retainer, spring, valve, valve seat) from
valve cavity.
3) Remove valve seat o-ring from valve cavity.
4) Inspect manifold for wear or damage.
5) Install new o-ring in valve cavity.
6) Insert valve assembly into valve cavity.
7) Replace valve cap and torque to specification.
NOTE: Only one valve kit is necessary to repair all the valves
in the pump. The kit includes new o-rings, valve seat, poppet, spring and
retainer. All are pre-assembled.
Ref 300875 Rev. A
02-12
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - TC Series “60”

TC Series “60”GENERAL PUMPA member of the Interpump GroupTRIPLEX TRIPLEXTriplex Plunger PumpSERVICING INSTRUCTIONSSERVICING PUMP PROCEDURESGeneral Pum

Seite 2 - Servicing Instructions

GENERAL PUMPA member of the Interpump GroupTC Series “60”Servicing InstructionsRemoving/Installing Manifold:1) Remove fasteners retaining manifold.2)

Seite 3

GENERAL PUMPA member of the Interpump GroupGGEENNEERRAALL PPUUMMPP 1174 Northland Drive • Mendota Heights, MN 55120Phone: (651)686-2199 • Fax: (800)

Seite 4 - TROUBLESHOOTING

Ref 300875 Rev. A02-12PROBLEM CAUSE REMEDYPulsationValve stuck open. Check all valves, remove foreign matter.Faulty pulsation damper.Check precharge;